Sugeng rawuh ing WINTPOWER

ATS Transfer Otomatis Ngalih Motorized Transfer Ngalih Generator Auto Gunakake

ATS Transfer Otomatis Ngalih Motorized Transfer Ngalih Generator Auto Gunakake

Rincian cepet:

200A ATS
400 ATS
1000 ATS
Ngalih Transfer Otomatis
Generator karo ATS
ATS kanggo Generator
Diesel generator ATS
Generator Transfer Otomatis
saklar tipe motorized
Socomec ATS
Kothak ATS Motorized


Detail Produk

Tag produk

Ora. MODEL SIRKUIT MEREK JENIS BUSBAR TEMBAGA Jinis kabinèt Ukuran Kabinet (H * W * D)
1 ATS-20-63 20-63A AISIKAI SKX2-63A 4P N/A A 500*400*250
2 ATS-100 100A AISIKAI SKX2-100A 4P N/A A 500*400*250
3 ATS-125 125A AISIKAI SKT1-125A 4P N/A B 600*500*300
4 ATS-160 160A AISIKAI SKT1-160A 4P N/A B 600*500*300
5 ATS-250 250A AISIKAI SKT1-250A 4P N/A B 600*500*300
6 ATS-400 400A AISIKAI SKT1-400A 4P N/A C 700*600*350
7 ATS-630 630A AISIKAI SKT1-630A 4P N/A C 700*600*350
8 ATS-800 800A AISIKAI SKT1-800A 4P Y GGD 1900*800*800
9 ATS-1250 1250A AISIKAI SKT1-1250A 4P Y GGD 1900*800*800
10 ATS-1600 1600A AISIKAI SKT1-1600A 4P Y GGD 1900*1000*800
11 ATS-2000 2000A AISIKAI SKT1-2000A 4P Y GGD 1900*1000*800
12 ATS-2500 2500A AISIKAI SKT1-2500A 4P Y GGD 1900*1000*800
13 ATS-3200 3200A AISIKAI SKT1-3200A 4P Y GGD 1900*1000*800

Cathetan:
1. lemantun ATS ngisor 250A kalebu 600 * 500 * 300 lemantun × 1;telung lampu indikator kanggo listrik (ijo), pembangkit listrik (abang), lan beban (kuning);kabel ATS dawane 3 meter kanthi soket penerbangan;kunci lawang siji;Sawetara blok terminal lan sekring, sekring, lsp.
2. 400A, 630A lemantun ATS kalebu 700 * 600 * 350 lemantun × 1;telung lampu indikator kanggo listrik (ijo), pembangkit listrik (abang), lan beban (kuning);kabel ATS dawane 3 meter kanthi soket penerbangan;kunci lawang siji;Sawetara blok terminal lan sekring, sekring, lsp.
3. Kabinet ATS 800A lan ndhuwur kalebu kabinèt GGD standar IP42 × 1;telung lampu indikator kanggo listrik (ijo), pembangkit listrik (abang), lan beban (kuning), voltmeter × 1, ngalih konversi voltase × 1, ammeter × 1 Trafo saiki × 3, ngalih konversi saiki × 1;Garis sambungan ATS dawane 3 meter kanthi soket penerbangan;kunci lawang siji;sawetara blok terminal kabel, wadhah sekring, lan sekring;bar tembaga
4. Iki jinis Staff dipetik ing voltase conventional 230 / 400V.Ngalih ATS kanggo unit kanthi voltase telung fase kurang saka 220V utawa luwih saka 440V kudu dipetik kanthi kapisah

Kabinet GGD

Kabinet tipe A, tipe B

Gambar 180

Gambar 181

Gambar 183

Gambar 184

Gambar 184

Gambar 184

1. Ringkesan
Bebarengan karo perkembangan masyarakat, masyarakat duwe panyuwunan kanggo pasokan listrik.Perusahaan kita miturut kabutuhan nyata pangguna lan ngembangake ATS daya dual intellectualized.Produk iki banget anti-jamming, dianggo stabil lan dipercaya, ora mung ngalih ing antarane rong kelompok daya, nanging uga nliti kanggo loro kelompok telung phase papat voltase.Nalika sembarang voltase phase banget, bisa kanthi otomatis ngalih daya mboten umum kanggo daya normal utawa ngirim metu weker.
2. Wilayah sing cocog
ATS cocog kanggo sistem sumber daya pindho AC50 / 60Hz, voltase dirating ing 600V, dirating saiki ing 2000A.Bisa éling antarane daya Perdana (N) lan daya siyaga (R) ngalih otomatis (uga bisa netepake kanggo ngalih manual). gardu trafo.Produk iki cocok kanggo panggonan penting kang ora ngidini Cut daya kurang voltase ngalih kabinet.
3. Sesuai karo standar
3.1 IEC60947-1 Aturan umum;
3.2 IEC60947-61(1998)《ATS》;
3.3 IEC947.2;
3.4 GB14048.11-2002;
4. Model produk

5. Wilayah sing ditrapake
5.1 Suhu lingkungan ora luwih saka +40 ℃ utawa luwih murah tinimbang -10 ℃
5.2 Panggonan Instalasi: Ketinggian ing sadhuwure segara ngirim ora luwih saka 2000m.
5.3 Kelas terkontaminasi
Kelas:3.Nduwe logam sing bisa mbledhos lan gas, cairan, bledug listrik sing bisa ngrusak insulasi.
5.4 kahanan atmosfer: Kelembapan relatif udhara ora ngluwihi 50% nalika suhu paling dhuwur yaiku +40 ℃, ing suhu kurang ora ngidini kelembapan relatif luwih dhuwur.Suhu rata-rata sasi paling udan ora ngluwihi +25 ℃, asor relatif rata-rata paling gedhe ing wulan iki ora ngluwihi 90%.
5.5 Yen kahanan sing kasebut ing ndhuwur ora bisa kepenak, rembugan karo pabrikan.
6. Struktur lan fungsi
6.1 Struktur
6.1.1 ATS digawe saka controller lan peralatan, antarane Unit kapisah kudu disambungake karo line disewakake, baris ora bisa ngluwihi 2 m.
6.1.2 Peralatan kasebut digawe saka motor elektro-motor positif, kontras, pemutus proteksi geni, interlocking mekanik, sisipan penerbangan, port sambungan lan liya-liyane.Kabeh bagean kasebut dipasang ing piring
6.1.3 Sistem cerdas iki (voltase kerja 400VAC, 50 / 60HZ) kanthi proteksi interlock ganda listrik mekanik, nyedhiyakake jaminan sing aman, dipercaya kanggo sampeyan.
6.2 Fungsi
Kontrol otomatis mriksa loro voltase ing wektu sing padha.Nalika voltase 115% luwih dhuwur tinimbang voltase dirating, banjur menehi kritik liwat voltase;nalika iku 60% -80% luwih murah tinimbang voltase dirating, banjur menehi kritik utang voltase.PC bakal ngadili asil lan mbuwang, ngirim mati break, mati break, generate listrik, uninstall, weker, etc.Hasil ing ndhuwur ditampilake ing panel kontrol sing bisa nyambung karo PC liwat port serial supaya pangguna bisa ngerteni sebabe.Kontrol cerdas bisa dipérang dadi telung jinis: Auto Gen / Auto Utama sing cocog ing antarane jaringan listrik;Auto Gen/Auto Manual cocog antarane jaringan listrik;Auto Gen / Auto Utama cocog antarane jaringan listrik lan ngasilake listrik.
6.2.1 Auto Gen / Auto Utama (R) cocog antarane jaringan listrik
The electrify initialization gawan supplier punika daya prima, nalika voltase saka prima daya (N) ana unconventionality, sawise mati break lan wektu tundha, prima daya (N) owah-owahan otomatis menyang posisi nul, sawise maneh mati break lan wektu tundha, otomatis owah-owahan kanggo daya siyaga (R), wektu tundha bisa netepake 0-30 detik
6.2.2 Auto Gen/Auto Manual cocog antarane jaringan listrik
Controller mriksa lan ngganti daya prima lan daya siyaga.Default initialization supplier punika daya prima, nalika voltase saka daya prima (N) ana unconventionality (Sembarang phase saka voltase sumber occurs liwat voltase, utang voltase, kurang saka phase), sawise mati break lan wektu tundha, daya prima (N) owah-owahan otomatis menyang posisi nul, sawise maneh mateni break lan wektu tundha, owah-owahan otomatis kanggo daya siyaga (R),
6.2.3 Jaringan listrik lan ngasilake listrik.

hgfdfgg (1)
(Incorporate ATS)

hgfdfgg (4)

hgfdfgg (3)
(Fissionable ATS)

hgfdfgg (2)

Daya prima pengontrol (N) lan daya siyaga (R) nindakake pemeriksaan, amarga daya siyaga (R) nyedhiyakake generator, voltase daya prima normal nalika ora ngasilake.Nalika voltase punika 60% -85% saka daya dirating, sistem Intelligence bisa menehi instruksi kanggo generator (klompok bandar nutup) .Sawise wektu tundha owah-owahan otomatis kanggo daya siyaga.Sawise voltase normal maneh, sistem cerdas misahake kanthi otomatis saka daya siyaga sawise wektu tundha, dadi sumber daya Perdana.
7. ATS njaba lan Instal Dimensi

8. Instal lan wiring diagram

Cathetan: Diagram pengkabelan iki cocog karo telung fase papat, nalika milih telung fase telung kabel, sumber daya kurva nol (NN) sing umum digunakake nampa papan tag N1 sikil, kurva nol sumber daya darurat (RN) nampa papan tag N2 sikil
Ing njaba sumber daya HD sing umum digunakake nyukupi syarat kanggo nglatih AC220V / 1A (suplai pangguna kanggo awake dhewe);Ing njaba sumber daya darurat TD nyukupi syarat kanggo nglatih AC220V / 1A (suplai pangguna kanggo awake dhewe);


  • Sadurunge:
  • Sabanjure:

  • Tulis pesen sampeyan ing kene lan kirimake menyang kita